logo

s1 s2 s3 s4

Protein Determination

Fat Determination

Fiber Determination
Sample Preparation

MicroLAB Digestor

Giá mới :

MICROLAB DIGESTOR - MWD SERIES

 

MWD Series with 12-vessel High-throughput processing capacity, meeting the needs of all kinds of sample preparation; Advanced multicore integrated optical fiber temperature control system, with precise temperature control and uniform digestion; Aerospace fiber outer vessel, COT real-time temperature and pressure abnormity monitoring system and other multiple safety protection design;

 

Free lifetime warranty commitment for the core part-magnetron;

 

The MWD microwave digester has been adhering to the principle and concept of "safe experiement", "efficient and convenient operation" and "durable use" from R&D to production. It can be widely used in routine laboratories and also applied under extreme conditions. MWD adopts advanced dual magnetron non-pulse frequency microwave heating technology, realizing the high power microwave heating & homogeneous heating; At the same time, MWD's highly intelligent man-machine dialogue operation system and wireless control module make the experiment process become efficient, convenient and humanized, and bring safe and comfortable experience to users.

 

Main features:

 

Optical fiber temperature control system is safe, meanwhile it can realize accurate temperature control. Optical fiber avoids the drawbacks ofantenna effect of conventional metal resistance temperature sensor, and solves multi-vessel digestion temperature deviation and unevenheating, adopts advanced multicore integrated optical fiber sensor, with an optical fiber diameter of 2 mm, its uses Teflon protectivecoating, and has small bending curvature, good fold-resistant and flexibility. The service life is 5 times longer than the single core optical fiber. MDW adopts advanced high-precision semiconductor pressure sensor, the whole conduction path conducts the anticorrosion treatment,realizing precise pressure control, with pressure precision of ±0.01MPa. MWD series has 2 magnetron, and its inverter microwave heating makes real-timeadjustment of microwave output power according to the temperature and pressurefeedback, thus the microwave f ield is more uniform and the control more precise.Inverter microwave heating can avoid the disadvantages of pause heating andfrequent startup, effectively protect the magnetron, and reduce energy loss. Doublemagnetron heating and professional microwave focusing design can make the magnetic field distribution inside the furnace chamber more even, ensuring theconsistency of the experimental sample digestion. MWD adopts aerospace composite fiber materials Xtra Fiber to make the outer vesselwhich is invincible that can withstand 80 MPa pressure, completely eliminating thepossibility of radial blasting. Its corrosion resistance, high temperature resistance andshock pressure and many performance indexes are excellent, fundamentally solvingthe dangers in the process of using.

 

MWD adopts ARM chip equipped with UCOS-II operating system, with stable and reliableoperation. It uses 7 inches of LCD touch screen, with touch control for operation, smooth andsimple. The screen gives the real-time display temperature- pressure curve. It has a built-inexpert method library, which can be edited and store user methods. Built-in COT real-time T/Pabnormity monitoring system can give automatic alarm when any reaction vessel hasabnormal temperature and pressure, and cut off the microwave so as to protect theinstrument. P version (MWD-P) has the Wi-Fi wireless control module, not only realizingpoint to point control between the computer and the microwave digestion instrument, butalso using a tablet PC to realize control and real time observation within the local area network (LAN). It brings better experience for "comfort experiment and safe experiment". P version also adopts double screen design and is equipped with 5 inches of LCD color displayfor real-time monitoring of digestion vessel operation inside the furnace chamber throughinternal camera.

 

With MWD 12-vessel of high throughput digestion capacity, it meets the pretreatment requirements of bulk samples. It adopts high-strength composite materials for enhancing strength, and reaches 1.7 tons of tensile test requirements, and its high pressure resistant frame is of thickening customization and canbear the high pressure during digestion. PEEK elastic tablet can resist high temperature, has larger rigidityand stable dimension, reach 19 MPa for bending strength and compression strength at 260°C, and canprotect PFA vessel cover from being damaged during the digestion. MWD digestion adopts thedesign of automatic pressure release, which puts an end to the occurrence of dangerous high pressureexplosion, and cancels safety membrane and other consumables, simple use and low cost.

 

MWD’s 316 stainless steel industrial furnace chamber adopts modular design concept, providing great convenience for the upgrading andmaintenance of equipment. The furnace door is made of multiple protective layers, and internal furnace chamber adopts multi-layer Tefloncoating, greatly improving the service life and safety guarantee of the instrument. The optimized groove structure design can eliminate themicrowave leakage. It will automatically cut off microwave when the door is opened naturally or forcibly, protecting the user's safety. Efficientexhaust system design can realize the fast and safe air cooling (drop from 200°C to 80°C within 15 minutes), improving operation efficiency.

 

Main Technical Parameters:

 

Power supply: 100100VAC/ 220240VAC 50/60Hz 16A

 

Microwave source: 2450MHz, dual magnetron design

 

Installed power: 2850W

 

Maximum output power: 1600W, microwave non-pulse continuous automatic frequency conversion control

 

Microwave chamber: 316L stainless steel chamber, applied with multi-layer anticorrosive Teflon inside and outside

 

Door design: Safety door designed based on the 3D directional explosion mechanism, with the integrated groove structure design of microwave leak prevention

 

Pressure monitoring system: High precision semiconductor pressure sensor, with pressure control range: 0-10MPa(1500psi), accuracy: ±0.01MPa

 

Temperature monitoring system: Multi-core integrated optical fiber temperature control system, Teflon protective coating, temperature measuring range: -40-305°C, accuracy: ±0.1°C

 

Passive protection system: COT real-time temperature and pressure monitoring system, automaticly alarm when any reaction tank has abnormal T/P, and cut off the microwave immediately to protect the user and instrument

 

Software: ARM chip equipped with UCOS-II operating system for multi-task operation, MWD equips with 7 inch LCD color touch screen, and connected to computer for remote control.

 

Wireless control system: MWD-P version is equipped with Wi-Fi wireless control module, tablet PC can be used to realize control and real-time observation of the internal operation inside furnace chamber. Communication interface: MWD-P version is equipped with 232 serial port and USB interface.Video monitoring: MWD-P version is equipped with 5 inch LCD color screen, which can conduct the real-time monitoring of digestion tank operation inside the chamber through the internal camera.

 

Chamber exhaust system:High-power corrosion-resisting turbine fan, with turbulent and efficient air cooling, fast 15 min cooling from 200°C to 80°C.

 

Working environment: 0 ~40°C/ 15~80% RH

 

Physical size / weight: 0~40°C/ 15~80% RH

 

MK-100 Closed High-pressure Reaction:

 

Maximum design pressure: 15MPa (2250psi)

 

Maximum design temperature: 300°C

 

Inner vessel volume: 100ml

 

Tank frame materials: PP&glass fiber high-strengthcomposite materials

 

Outer vessel material: aerospace composite fibermaterials Xtra Fiber

 

Inter vessel material: TFM (reinforced modified PTFE)

 

Largest batch processing capacity: 12 vessels

 

Catalogue for Dowload

MicroLAB

@ Copyright and Develop by ORBYLAST